Engraving & cutting guide · 8 min read

Fiber laser cutting machine installation: site preparation and commissioning

Updated · Written by the Maxwave applications team, checked by an engineer before publication · Editorial standards

Short answer

A fiber laser cutter is installed in four stages: prepare the site, place and level the machine, connect power, gas and cooling, then commission the control system and the capacitive height controller. A 3 kW machine draws about 22–27 kVA and a 12 kW machine 64.7 kVA; enclosed machines weigh 7.5–8 t. The height controller is commissioned in a fixed order: servo parameters, travel limits, motor direction, servo calibration, homing and capacitance calibration, then following gain and height. Most of the work is done before the crate opens.

Key takeaways

  • Plan the supply first: about 22 kVA for a 3 kW enclosed cutter, 35.6 kVA at 6 kW and 64.7 kVA at 12 kW, on 380 V 50/60 Hz or 220 V 60 Hz. Add a voltage stabilizer where the mains is unstable.
  • Floor and space: the enclosed MW-FLX3015 weighs over 7.5 t (over 8 t at 12 kW) and measures 8850 × 2820 × 2040 mm; the MW-FLSP sheet and tube cutter weighs over 5 t on 5062 × 3962 mm.
  • Gas purity matters for cut quality: the reference cutting data assumes oxygen at 99.99 % and nitrogen at 99.999 %, with pressure measured at the cutting head.
  • Earth the height controller's FG pin to the machine body with less than 10 Ω DC resistance, or the capacitive height following becomes unreliable.
  • Commission the height controller in order: servo parameters, travel limits, motor direction, servo calibration, homing, capacitance calibration, then following gain (1–30) and height.
Screw air compressor with receiver tank beside rows of oxygen and nitrogen cylinders in a cutting workshop
Air compressor and cutting-gas cylinders, partner factory
Close-up of a fiber laser cutting head and copper nozzle above the slat bed; the nozzle is the sensing electrode of the capacitive height controller
Cutting head and nozzle over the slat bed

Installing a fiber laser cutter goes fastest when the site is ready before the machine arrives. This guide lists what to prepare for Maxwave’s cutters, then how the control system is connected and the height controller commissioned.

Where the numbers come from. Site requirements are from Maxwave’s configuration sheets for the MW-FLX3015, the MW-FLSP sheet and tube cutter and the 1530 cutter. The commissioning steps are from BOCHU’s installation training manual for overseas customers, which covers the BMC1204 motion control card, the BCS100 height controller and CypCut software used on many of our machines. Gas purity is from the source makers’ cutting data in our cutting parameters guide. Points marked “general practice” are standard workshop advice rather than figures from those documents.

1. Prepare the site

MW-FLX3015, 3 / 6 kW MW-FLX3015, 12 kW MW-FLSP, 3 kW 1530 cutter
Supply 380 V 50/60 Hz or 220 V 60 Hz 380 V 50/60 Hz or 220 V 60 Hz 380 V 50/60 Hz or 220 V 60 Hz 380 V
Power demand 22 kVA / 35.6 kVA 64.7 kVA Under 27 kVA See quotation
Weight Over 7.5 t Over 8.0 t Over 5 t About 5.5 t
Machine size 8850 × 2820 × 2040 mm 8850 × 2820 × 2040 mm 5062 × 3962 × 1870 mm 1500 × 3000 mm bed plus source cabinet
Cooling Dual-temperature chiller; cabinet air conditioner Dual-temperature chiller; cabinet air conditioner Dual-temperature chiller; cabinet air conditioner Chiller
  • Power. Run a dedicated supply sized for the demand above. Where the voltage swings, order the voltage stabilizer matched to your mains.
  • Floor. A level concrete floor that carries the machine’s weight, with space on the loading side for sheet and pallets and room behind for service (general practice).
  • Gas. Oxygen of 99.99 % purity for carbon steel and nitrogen of 99.999 % for stainless steel and aluminium; compressed air for air cutting. Size regulators and pipes for the pressures in the cutting tables, which are measured at the head.
  • Extraction. The enclosed cutters have zoned extraction under the bed; connect it to a fume extractor or duct sized for the bed area (general practice).
  • Environment. Keep the chiller and the electrical cabinet out of direct sun and dust. The industrial air conditioner on the enclosed and sheet-and-tube cutters keeps the cabinet closed and cool in hot workshops.

2. Place and connect the machine

  1. Unload with equipment rated for the weight, and set the machine on its final spot before connecting anything (general practice).
  2. Level the bed, then connect the chiller, the gas lines and the extraction.
  3. Connect the main supply through the stabilizer, if fitted, and check the earth.

3. Control system: card, terminal board and laser

On machines with a BOCHU BMC1204 control card, the card sits in a PCI slot of the industrial PC.

  • Install the card with the PC switched off, wearing an antistatic strap or after touching earthed metal. Start the PC, cancel the “Found New Hardware” wizard, then install CypCut, which also installs the card driver and the software dongle. The card should then appear in the device manager.
  • If the card is not found, reseat it or move it to another PCI slot and reinstall CypCut. A yellow exclamation mark with a correct device ID means the software install failed; reinstall it.
  • Terminal board. The card connects to a BCL3762 terminal board with a 15-pin servo interface for each of X and Y, the laser signals, a 24 V power input, limit and origin switches, 18 outputs and 12 inputs.
  • Servo drives must take “pulse + direction” commands. Supply 24 V to the terminal board before the first servo trial, and connect the signal cable’s shield to the drive casing.

4. Commission the height controller

The BCS100 keeps the nozzle at a constant height above the sheet by measuring capacitance. Before you start, connect its FG pin to the machine body, and make sure the preamplifier casing is in good contact with the machine: the DC resistance to the machine body must stay below 10 Ω, or the height following will be poor.

Then work through the steps in this order:

  1. Servo parameters. Set the Z-axis servo drive to speed mode. BOCHU gives recommended values for Panasonic A5 and Yaskawa Σ-V drives.
  2. Mechanical parameters in the BCS100’s parameter screen.
  3. Travel limits. Block the upper and lower limit switches by hand and check that the screen shows each limit as enabled.
  4. Motor direction. Jog the Z axis open-loop and check that it moves the right way; if not, change the servo direction, and if the encoder counts backwards, change the encoder direction.
  5. Servo calibration removes the servo’s zero drift.
  6. Homing. Return to the origin and switch on homing at power-up.
  7. Capacitance calibration of the nozzle sensor, so the controller can turn capacitance into distance.
  8. Following gain and height. Gain runs from 1 to 30. A higher gain follows faster and with less error but can start to oscillate, so raise it step by step. Set the cutting height in 0.1 mm steps; in Ethernet mode, CypCut sets it.

On the main screen, “dynamic error” shows how far the nozzle is from the set height while following, and the capacitance value falls to zero if the nozzle touches the sheet.

Machines with other controllers, such as the Bochu FSCUT8000 on the 12 kW MW-FLX3015, follow the same order of checks; our engineers set them up with you.

5. First cuts and training

Cut test strips on your own plate, starting from the cutting parameters for your source and thickness, and save the settings for each material. If we tested your samples before shipping, the settings we used are already on the machine.

Most machines arrive ready to run, and we guide installation by video call; for larger machines, ask about on-site installation when you order. Operator training is free, at our Wuhan factory or by video. What else comes with every machine is on our service and warranty page.

FAQ

Questions buyers ask

What power supply does a fiber laser cutting machine need?

Usually 380 V three-phase at 50 or 60 Hz; some models also run on 220 V at 60 Hz. The demand grows with the source: about 22 kVA for a 3 kW enclosed cutter, under 27 kVA for a 3 kW sheet and tube cutter, 35.6 kVA at 6 kW and 64.7 kVA at 12 kW. Check your supply and add a voltage stabilizer where the mains is unstable.

How heavy is a fiber laser cutter, and what floor does it need?

An open 1500 × 3000 mm cutter weighs about 5.5 t, a sheet and tube cutter over 5 t and an enclosed 3015 cutter 7.5–8 t. Place it on a level concrete floor that carries that load, with room around it for loading sheet and for service, and plan the unloading equipment before delivery.

What is capacitance calibration on a laser cutter?

The height controller measures the capacitance between the nozzle and the sheet to keep a constant cutting height. Calibration records how the capacitance changes with distance for your nozzle and cable, so the controller can turn a reading into a height. Run it after the servo calibration and homing, and again after changing the nozzle or the head.

Do you install the machine on site?

Most machines arrive ready to run, and our engineers guide installation by video call. For larger machines, ask about on-site installation when you order. Either way, operator training is free.

From the Maxwave range

Machines for this job

Need a different configuration?

This website shows part of our range. Whatever you need, from a machine we don’t list to a complete production line, we supply it as one solution. Contact us any time.

Keep reading

Get a quote